SECTION 7.2 CASE IH 7010, 8010, 7120, 8120, 88 SERIES

Form 169006

31

Revision D

3. Remove coupler (L) from combine, and clean

mating surfaces.

4. Position onto adapter receptacle (G), and

push handle (K) to engage coupler pins into
receptacle.

5. Push handle to “closed position” until lock

button (J) snaps out.

g. Remove cover on adapter electrical receptacle

(N). See illustration on previous page.

h. Remove electrical connector (M) from storage

cup on combine, and route to adapter receptacle.

i.

Align lugs on connector with slots in receptacle,
push connector onto receptacle, and turn collar
on connector to lock it in place.

j. Rotate disc (O) on adapter driveline storage

hook, and remove driveline from hook.

k. Pull back collar (P) on end of driveline, and push

onto combine output shaft (Q) until collar locks.

l. Disengage both adapter float locks by moving

latch (R) away from adapter, and moving lever
(S) at each lock to “lowest position”.

S

LOCK

UNLOCK

R

J

G

K

M

O

Q

P

L