SECTION 8.2 FD70 FLEXDRAPER AND ADAPTER

Form 169006

78

Revision D

p. Rotate latch (Q) with a 15/16 wrench (or

equivalent) on hex (T) to raise feed deck so that
bolt (P) can be re-installed. Repeat for other side
of feed deck.

q. Attach the wing float linkage to the adapter as

follows:

1. Remove pin (U) from bracket (if installed).

2. Re-install pin with springs (V), and secure

with hairpin.

r. Connect knife and draper drive hydraulics as

shown above, matching colored plastic cable ties.

s. If quick disconnects are installed, connect as

follows:

1.

Remove covers (if installed) from

receptacles and hose ends.

2. Check connectors and clean if required.

3. Push hose connector onto mating receptacle

until collar on receptacle snaps into lock
position.

NOTE

Ensure hoses are clear of driveline and
adjacent structure.

t. Attach

electrical

connector as follows:

1. Remove cover on receptacle.

2. Align lugs on connector with slots in

receptacle, push connector onto receptacle
and turn collar on connector to lock it in
place.

3. Attach cover to mating cover on combine

wiring harness.

u. Raise and lower header and reel a few times to

allow trapped air to pass back to the reservoir.

NOTE

It is not necessary to bleed the system
by loosening fittings.

v. Check float and if the header is level. If

adjustments are required, refer to Section 9.11.3
Header Float, and Section 9.14 HEADER
LEVELLING.

DRAPER DRIVE

RETURN

ELECTRICAL

KNIFE DRIVE

CASE DRAIN

(DOUBLE KNIFE)

Q

T

U

V