Caution – MacDon FD70 for Combine Operators User Manual

Page 150

Advertising
background image

SECTION 10. MAINTENANCE AND SERVICING

Form 169006

148

Revision D

10.5.4

Auger Drive Chain Lubrication

Lubricate auger drive chain every 100 hours.
This can be done with the adapter attached to the
combine, but is easier if the adapter is detached.

Refer to following illustration, and proceed as
follows:

a. Loosen nut (A). Remove clip (B) and cover (C).

b. Liberally apply grease to chain.

c. Re-install cover (B) with clip (C), and tighten nut

(A).

10.5.5

Main Drive Gearbox Lubrication

10.5.5.1 Oil

Level

Check oil level every 100 hours as follows:

CAUTION

Stop engine, and remove key from ignition
before leaving Operator's seat for any reason.
A child or even a pet could engage an idling
machine.

a. Set cutterbar to working position.

b. Remove oil level plug (D). Level should be to

bottom of hole.

c. Check plug for accumulation of filings, and clean

if necessary.

d. Replace drain plug, and add oil if required. See

next section.

10.5.5.2 Adding

Oil

a. Lower cutterbar to ground. Gearbox must be in

working position.

b. Remove drain plug (D) and filler plug (E).

c. Add SAE 85W-140 oil at (E) until it runs out of

hole (D).

d. Replace oil level plug (D) and filler plug (E).

C

B

A

E

D

Advertising
This manual is related to the following products: