Click "apply changes" to save the configuration, Configure device identity – Rockwell Automation 193-ETN E1 Plus EtherNet Side Mount Module User Manual User Manual
Page 59

Rockwell Automation Publication 193-UM012B-EN-P - June 2011
59
Chapter 5
4.
Enter the information into the email notification fields as described below.
5.
Select the specific fault and warning notifications to send to the email
recipient. These can be changed after the initial configuration.
6.
Click "Apply Changes" to save the configuration.
Configure Device Identity
The Device Identity properties populate the notification email subject and body.
To configure the Device Identity, perform these steps:
Email Recipient
The email address of the person who will receive the notifications.
Email Sender
The email address from which the notification will be sent.
SMTP Server
The SMTP server address. Ask your network administration what address
to use.
SMTP Username
The username for the SMTP server. Ask your network administration what
username to use.
SMTP Password
The password for the SMTP server. Ask your network administration what
password to use.
SMTP Port
The SMTP Server Port. Ask your network administration what port number
to use (Port 25 is a common SMTP port).