The following instance attributes are implemented for all parameter attributes:
Table 47 - Ethernet Link Object Instance Attributes
Attribute ID
Access Rule
Name
Data Type
Value
1
Get
Interface Speed
UDINT
10 or 100
2
Get
Interface Flags
DWORD
3
Get
Physical Address
ARRAY of 6 USINTs
MAC Address
4
Get
Interface Counters
Structure of:
In Octets
UDINT
N/A
In Ucast Packets
UDINT
N/A
In NUcast Packets
UDINT
N/A
In Discards
UDINT
N/A
In Errors
UDINT
N/A
In Unknown Protos
UDINT
N/A
Out Octets
UDINT
N/A
Out Ucast Packets
UDINT
N/A
Out NUcast Packets
UDINT
N/A
Out Discards
UDINT
N/A
Out Errors
UDINT
N/A
5
Get
Media Counters
Structure of:
Alignment Errors
UDINT
N/A
FCS Errors
UDINT
N/A
Single Collisions
UDINT
N/A
Multiple Collisions
UDINT
N/A
SQE Test Errors
UDINT
0
Deferred Transmission
UDINT
N/A
Late Collisions
UDINT
N/A
Excessive Collisions
UDINT
N/A
MAC Transmit Errors
UDINT
N/A
Carrier Sense Errors
UDINT
N/A
Frame Too Long
UDINT
N/A
MAC Receive Errors
UDINT
N/A
6
Get/Set
Interface Control
Structure of:
Control Bits
WORD
N/A
Forces Interface Speed
UINT
N/A