Rockwell Automation 1336T FORCE Series B User Manual
Page 168

Chapter 5
Programming Parameters
5–42
Powerup/Diagnostic Fault Status
[PwrUp Flt Status]
Parameter Number
80
Parameter Type
Source
Display Units
Bits
Drive Units
None
Factory Default
0000 0000 0000 0000
Minimum Value
0000 0000 0000 0000
Maximum Value
1111 1111 1111 1111
Enums:
This word parameter indicates a fault
condition which has been detected during
power up or reset of the drive. When a bit
is “1”, the condition is true, otherwise the
condition is false.
Bit
Condition
0
CP PROM Failure
1
CP Internal RAM Failure
2
CP External RAM Failure
3
CP Stack RAM Failure
4
VP Dualport RAM Failure detected by CP
5
Not Used
6
Not Used
7
Not Used
8
VP EPROM Failure
Bit
Condition
9
VP Internal RAM Failure
10
VP External RAM Failure
11
VP Stack RAM Failure
12
CP Dualport RAM Failure detected by VP
13
AP Dualport Ram Failure detected by VP
14
Base Drive EE Failure
15
Reserved, Leave Zero
CP Configurable Fault Status
[CP Flt Status]
Parameter Number
82
Parameter Type
Source
Display Units
Bits
Drive Units
None
Factory Default
0000 0000 0000 0000
Minimum Value
0000 0000 0000 0000
Maximum Value
1111 1111 1111 1111
Enums:
This word parameter indicates conditions
detected by the Current Processor (CP)
that has been configured to report as a
Drive fault condition. Each configuration
bit matches the bit definitions of Parameter
84, 86 and 87. When a bit is “1” the
condition is true, otherwise the condition is
false.
Non–configurable Fault Status
[Ncfg Flt Status]
Parameter Number
81
Parameter Type
Source
Display Units
Bits
Drive Units
None
Factory Default
0000 0000 0000 0000
Minimum Value
0000 0000 0000 0000
Maximum Value
1111 1111 1111 1111
Enums:
This word parameter indicates fault condi-
tions in the drive that Cannot be configured
as warnings. When a bit is “1”, the condi-
tion is true, otherwise the condition is false.
Bits 0 – 3 are detected by hardware. Bits
4–15 are detected by software.
Bit
Condition
0
DC Bus Overvoltage Trip
1
Transistor Desaturation
2
Ground Fault
3
Instantaneous Overcurrent
4
Adapter Comm Loss detected by CP
5
Master/Slave Cable Loss
Bit
Condition
0
Bus Ridethrough Timeout
1
Bus Precharge Timeout
2
Bus Drop (150 volts)
Bit
Condition
10
Analog Power Supply Tolerance
11
Autocommisioning or Transistor Diagnostic Failure
12
Inverter Temperature Trip
13
Software Malfunction detected by VP
14
Not Used
15
Reserved, Leave Zero
Bit
Condition
3
Bus Undervoltage
4
Bus Drop Cycles > 5
5
Fast Fluxup Current < 50%
Bit
Condition
6
Master/Slave Enable Timeout
7
Not Used
8
Handshake Timeout VP
9
Absolute Overspeed
VP Configurable Fault Status
[VP Flt Status]
Parameter Number
83
Parameter Type
Source
Display Units
Bits
Drive Units
None
Factory Default
0000 0000 0000 0000
Minimum Value
0000 0000 0000 0000
Maximum Value
1111 1111 1111 1111
Enums:
This word parameter indicates conditions
detected by the Velocity Processor (VP)
that have been configured to report as fault
conditions. Each configuration bit matches
the definitions of Parameter 85, 88 and 89.
When a bit is “1” the condition is true,
otherwise the condition is false.
Bit
Condition
0
Feedback Loss
1
Inverter Overtemp Pending
2
Motor Overtemperature Tripped
3
Motor Overload Pending
4
Motor Overload Trip
Bit
Condition
10
Math Limit
11
Dynamic Brake Overtemperature
12
AC Motor Contactor Failure
13
Inverter Overload Pending (IT)
14
Drive to Drive Communication Fault
15
Inverter Overload Trip (IT)
Bit
Condition
5
Motor stalled
6
External Fault
7
RMS Fault
8
Not Used
9
Parameter Limit