The Hardware Testpoints on the PLC Comm Adapter Board are illustrated in
Figure 6.12. The accompanying table details the expected output from each
testpoint.
Figure 6.12
PLC Comm Board Test Points
AP
Status
LANGUAGE
MODULE
DP Status
1
CH A High
J5
TP1
Port 1
DOMINO
ADAPTER
RIO
Channel A
Communication Modes
U2
U3
U4
U5
10
TB20
TB21
1
19
CH A Low
CH B Low
CH B High
D3
D6
D8
D10
D12
D13
D14
D15
CH A
Status
CH B
Status
J7
D1
D2
Port 2
TP2
TP3
TP4
TP5
ADC Inputs
DAC Inputs
J1
Main Control
Interface
Drive Permissives
J4
J3
120 V
RIO
Channel B
BRAM
Enable
Ref
D4
D5
Fault Out
Ext Fault
D7
Norm Stop
Motor Thermo
D9
Drive Enable
D11
24 V
120 V
24 V
120 V
24 V
120 V
24 V
J11
J10
J9
J8
Drive En
M Therm
N Stop
X Flt
EN
DIS
Fuse
1 – 4
TP24
+10V Ref
TP25
–10V Ref
↑
ON
↑
ON
↑
ON
↑
ON
DGND +5V
+15V
–15V
AGND
TP9 TP10 TP11 TP12 TP13 TP14
TP19
TP20 TP21 TP22 TP23
TP15 TP16 TP17 TP18
TP1
TP2
TP3
TP4
TP5
TP9
TP10
TP11
TP12
TP13
TP14
Testpoint
DGND
+5V
+15V
AGND
–15V
Not Used
Not Used
ISO +12 VDC
ISO –5V
ISO GND
IGND
Application
TP15
TP16
TP17
TP18
TP19
TP20
TP21
TP22
TP23
TP24
TP25
Testpoint
AIN – 1
AIN – 2
AIN – 3
AIN – 4
+12V
AOUT – 1
AOUT – 2
AOUT – 3
AOUT – 4
+10V Ref
–10V Ref
Application