Rockwell Automation 1336T FORCE Series B User Manual
Page 81

Chapter 3
Programming Terminals
3–15
AB0270A
or
or
or
(continued)
Control Status Mode
Warning Queue/Clear Warnings
This menu provides a means to view the
warning queue and clear it when desired.
From the Control Status menu, press the
Increment (or Decrement) key until
“Warning Queue” is displayed.
Press Enter.
Press the Increment (or Decrement) key
until “View Queue” is displayed.
Press Enter. The warning queue will be
displayed.
Use the Increment (or Decrement) key
to scroll through the list.
If you wish to view the time and date of
the warning occurrence, press the Enter
key.
To clear the warning queue, press
ESCape. Then use the Increment/Decre-
ment keys to select “Clear Queue.”
Press Enter. Please note that “Clear
Queue” will not clear active warnings.
Control Status
Warning Queue
Warning Queue
View Queue
Vel Fdbk Lvl
F 5048 5
1:20:22 1/1
Warning Queue
Clear Queue
or
Reset Sequence
or
A reset sequence is available on Series B
HIMs with 1.06 or later software.
From the Startup Completed display
press the Enter key.
Press the Increment (or Decrement) key
until “Startup Reset Sequence” is
displayed. Press Enter.
Press the Enter key again to relaunch the
Startup sequence.
Start Up
Completed
Start Up
Reset Sequence
Entering Start Up
Press ‘ENTER’