Chapter 5
Programming Parameters

5–55

External Torque Step
[Ext Torque Step]

Parameter Number

166

Parameter Type

Sink

Display Units

x.x %

Drive Units

4096 @ rated motor torque

Factory Default

0.0%

Minimum Value

– 800.0%

Maximum Value

+ 800.0%

This parameter supplies an external torque
offset to the Drive. The Ext Torque Step is
summed with the Torque Mode Sel (P53)
output prior to the Torque Limiter.

Internal Torque Reference
[Int Torque Ref]

Parameter Number

167

Parameter Type

Source

Display Units

+/– x.x %

Drive Units

4096 = rated torque

Factory Default

+0.0 %

Minimum Value

–800.0%

Maximum Value

+800.0%

This parameter shows the value of torque
reference that is present at the output of
the torque limiter.

Internal Iq Reference
[Internal Iq Ref]

Parameter Number

168

Parameter Type

Source

Display Units

+/– x.x%

Drive Units

4096 = rated torque

Factory Default

+0.0 %

Minimum Value

– 800.0%

Maximum Value

+ 800.0%

This parameter shows the value of the Iq
reference that is present at the output of
the Iq rate limiter. 4096 is 100% Iq motor
current.

Torque Reference Testpoint Data
[Torque Ref TP]

Parameter Number

172

Parameter Type

Source

Display Units

+/– x.x%

Drive Units

4096 = 100% (1.0 pu)

Factory Default

+ 0.0%

Minimum Value

– 800.0%

Maximum Value

+ 800.0%

This parameter indicates the value of the
internal location selected by the Torq Ref
TP Sel parameter, P173. The select will
allow this parameter to be used as a test-
point for the torque
reference input.

Torque Reference Testpoint Select
[Torq Ref TP Sel]

Parameter Number

173

Parameter Type

Sink

Display Units

x

Drive Units

None

Factory Default

0

Minimum Value

0

Maximum Value

31

Enums:

This parameter selects which internal loca-
tion of the torque reference will become the
testpoint value. The value based on the
select will be stored in the Torque Ref TP
(P172).

Select Value

Torque Reference Access Point

Select Value

Torque Reference Access Point

0

Zero

17

Torque Reference Status

1

NTC Limit

18

Torque Reference Math Overflow Status

2

Inverter Current Limit

19

Active Torque Mode

3

Overload Current Limit

20

Positive Torque Power Limit

4

Positive IQ Limit

21

Negative Torque Power Limit

5

Negative Iq Limit

22

Rated Inverter Current

6

Zero (Not Used)

23

Averaged Motor Flux

7

Torque Limit (Low)

24

lq Current Reference Adjusted for Motor Range

8

Torque Limit (High)

25

lq Sum

9

Scaled External Torque Reference 1

26

Torque Mode Select lq Ref

10

Scaled External Torque Reference 2

27

Inverter Gain

11

Torque Sum

28

Motor Range

12

Torque Command

29

Motor to Inverter Current Ratio

13

Filtered Torque Reference

30

DC Bus Ride-Thru Latch

14

Unlimited Iq Reference

31

Current Processor Regulation Active Flag

15

Current Limited Iq Reference

16

Filtered Iq Reference