Rockwell Automation 1336T FORCE Series B User Manual
Page 195

Chapter 5
Programming Parameters
5–69
Motor Inductance Test Errors
[Lo Test Error]
Parameter Number
295
Parameter Type
Source
Display Units
Bits
Drive Units
None
Factory Default
0000 0000 0000 0000
Minimum Value
0000 0000 0000 0000
Maximum Value
1111 1111 1111 1111
This parameter indicates an error condition
detected during the motor inductance test.
1 = Drive condition true
0 = Drive condition false
Bits are defined as follows:
Bit
Condition
0
Motor Not at Zero Speed
1
Sign Error
2
Zero Current
3
A/D Overflow at min gain
4
Enable drop out
5
Sign error/Overflow
6 to 15
Reserved
Motor Stator Resistance Test Errors
[Rs Test Error]
Parameter Number
296
Parameter Type
Source
Display Units
Bits
Drive Units
None
Factory Default
0000 0000 0000 0000
Minimum Value
0000 0000 0000 0000
Maximum Value
1111 1111 1111 1111
Low frequency gain boost of the frequency
regulator in sensorless mode. This param-
eter must not be changed.
Bits are defined as follows:
Bit
Condition
0
Motor Not at Zero Speed
1
Sign Error
2
Not Used
3
Zero Current
4
Not Used
5
Software Error
6
Not Used
7
Enable Drop Out
8–15
Reserved
Motor Flux (Id) Test Errors
[Id Test Error]
Parameter Number
297
Parameter Type
Source
Display Units
Bits
Drive Units
None
Factory Default
0000 0000 0000 0000
Minimum Value
0000 0000 0000 0000
Maximum Value
1111 1111 1111 1111
This parameter indicates an error condition
detected during the motor flux (Id) test. If a
bit is set to “1” the Drive condition is true,
otherwise the condition is false.
Torque Block Calculation Errors
[Torq Calc. Error]
Parameter Number
298
Parameter Type
Source
Display Units
Bits
Drive Units
None
Factory Default
0000 0000 0000 0000
Minimum Value
0000 0000 0000 0000
Maximum Value
1111 1111 1111 1111
Enums:
This word parameter indicates an error
condition which has been detected during
the torque block calculations. If a bit is set
to “1” the Drive condition is true, otherwise
the condition is false.
Bits are defined as:
Bit
Condition
0
1 to 15
Negative or Zero Slip
Reserved
Bits are defined as follows:
Bit
Condition
0
Autotune Speed Low (30% min)
1
Identified Id < zero
2
Identified Id > 100% motor current
3
Enable drop out
4–15
Reserved