Rockwell Automation 1336T FORCE Series B User Manual
Page 205

Chapter 5
Programming Parameters
5–79
SCANport Analog2 Select
[SB Analog2 Sel]
Parameter Number
367
Parameter Type
Sink
Display Units
x
Drive Units
None
Factory Default
1
Minimum Value
1
Maximum Value
6
Enums:
This parameter selects which SCANport
analog device is used in parameter 368
‘SB Analog In 2’.
1
Scanport 1
2
Scanport 2
3
Scanport 3
4
Scanport 4
5
Scanport 5
6
Scanport 6
SCANport Analog2 In
[SB Analog2 In]
Parameter Number
368
Parameter Type
Source
Display Units
+/– x
Drive Units
None
Factory Default
0
Minimum Value
–32767
Maximum Value
+32767
This parameter displays the analog value
of the SCANport device selected in
parameter 367 ‘SP Analog2 Sel’.
SP Analog2 Scale
[SB Analog2 Scale]
Parameter Number
369
Parameter Type
Sink
Display Units
+/–x
Drive Units
+/– 1, 1 = 32767
Factory Default
1 (32767)
Minimum Value
–1 (–32767)
Maximum Value
1 (32767)
This parameter can be used to scale the
value in Parameter 368.
Analog Output 1
[Analog Out 1]
Parameter Number
370
Parameter Type
Sink
Display Units
+/–x
Drive Units
None
Factory Default
0
Minimum Value
–32767
Maximum Value
+32767
This parameter converts a +/– 32767
digital value to a +/– 10 volt output.
Analog Output 1 Offset
[An Out 1 Offset]
Parameter Number
371
Parameter Type
Sink
Display Units
+/– x.xxx volt
Drive Units
205 = 1 volt
Factory Default
+0.000 volt
Minimum Value
–20.000 volt
Maximum Value
+20.000 volt
This parameter determines the offset
applied to the raw analog output 1. The
offset is applied after the scale factor.