Rockwell Automation 1336T FORCE Series B User Manual

Page 57

Advertising
background image

Chapter 2
Installation/Wiring

2–37

Figure 2.24.
Input Mode Selection & Typical TB3 Connections

19

20

21

22

23

24

25

26

27

28

29

30

Status

Not Stop/Clear Fault

3

Common

Status

Status

Status

Common

Status

Status

Status

Common

Enable

3

[Input Mode] 1

Factory Default

19

20

21

22

23

24

25

26

27

28

29

30

Start

Not Stop/Clear Fault

3,7,8

Common

Rev/Fwd

5

Auxiliary 3

Common

Speed Select 2

1

Speed Select 1

1

Common

Enable

3

Jog

Stop

Type

2nd/1st

Accel

Digital

Pot Up

Speed

Select 3

1

Speed

Select 3

1

2nd/1st

Decel

Digital

Pot Dn

2

3

4

5,27

9

6

Mode

[Input Mode] 2–6, 17, 18

Three–Wire Control with Single–Source Reversing

1

See Speed Select Table on previous page.

2

Drive must be stopped to take Local Control.
Control by all other adapters is disabled (except Stop).

3

These inputs must be present before drive will start.

4

Bit 0 of [Direction Mask] must = 1 .

5

For Common Bus – Precharge Enable.

6

Bit 12 of Para 59 Logic Options must = 0 for Reverse Direction Control.

7

Soft Fault Reset Only, Must Cycle Power to Drive to Clear Hard Fault; Hard Fault = See Troubleshooting Section

8

Soft Fault Refer to Para 59 to Configure Start & Stop Type.

9 Digital Pot Value Zeroed When Stop Asserted.

Proc

Trim

Local

Control

2

Jog

Flux En

Jog

Ramp

Reset

17

18

Advertising