1. From Control Panel > Administrative Tools, run the IIS Admin Manager.

Expand the virtual directory FactoryTalk/Security/Web Service, then right click
on FactoryTalk\Security\WebService\200810.asmx to select Browse. You can
now test the FactoryTalk Security (FTSecurity) service interfaces.

2. From Control Panel > Administrative Tools, run Services.

Change the startup type for ASP.NET State Service to automatic. Ensure that the
asp.net service is started. This deploys the web service to the following URL:

http://<host name>:<port_number>/ FactoryTalk/Security/WebService/
200810.asmx.

3. Configure FactoryTalk Directory.

a) Create an administrative user on the local machine that hosts the FactoryTalk
Historian servers.

b) Open the FactoryTalk Administration Console, and create a corresponding user
with the same name and password. Add it to Administrator group.

4. From the Windows menu, go to FactoryTalk Tools > FactoryTalk Directory

Configuration Wizard and select Network Directory.

Enter the administrator user and password, and re-enter it. Wait for a moment and
check the summary. If all is successful, close the Network Directory.