Chapter 4

Ladder-Program Interfaces

4-4

Example 2:

CTV

#

N7:0

FF01

D08O

5

Example 2 reads the lower byte of elements 0 through 4 of file 7 and writes
them to addresses FF01 through FF09 (odd bytes only).

Data in PLC Processor

Result of Transfer to VMEbus

Address

Data (hex)

Address

Data

Address

N7:0

0044

FF00

00 44

FF01

N7:1

0055

FF02

00 55

FF03

N7:2

0066

FF04

00 66

FF05

N7:3

2077

FF06

00 77

FF07

N7:4

3088

FF08

00 88

FF09

Copy from VME

This message tells the PLC-5/VME processor to read the specified amount
of data from VMEbus memory using VMEbus read operations and write it
into the specified file. As with the continuous-copy operations, if the
address falls within the enabled VMEbus slave memory of the
PLC-5/VME processor, the data is read from this dual-port memory
directly without doing actual VMEbus operations.

Example 1:

CFV

D004

D08

#

N8:0

4

The example above performs eight D08 read operations beginning at VME
address D004 and then writes the data as four elements (0-3) in file N8.

Example 2:

CFV

FF01

D08B

#

N7:0

3

Example 2 reads three consecutive bytes starting at FF01 in the VME A16
address space and writes the data into three elements in file N7:0.

Data on VMEbus

Result of Transfer to PLC Processor

Address

Data (hex)

Address

Data

Address

N7:0

0022

FF00

11 22

FF01

N7:1

0033

FF02

33 44

FF03

N7:2

0044

FF04

55 66

FF05

Advertising