Chapter 4 – Rockwell Automation 1785-Vx0B, D17856.5.9 PLC-5 VME VMEbus Programmable Controllers User Manual User Manual

Page 56

Advertising
background image

Chapter 4

Ladder-Program Interfaces

4-9

Table 4.B
Fields for the Physical Structure of the VME Status File

Word

Code

Function

Explanation

0

1

VSYSF

Describes the state of the VME
SYSFAIL signal. Read only.

If 0, SYSFAIL is being asserted (including by the PLC-5/VME processor);
if 1, SYSFAIL is not being asserted.

0

1

PSYSF

Read only

Describes the state of the VME SYSFAIL signal as being driven by the PLC-5/VME
processor. If 0, the PLC-5/VME processor is asserting SYSFAIL; if 1, it is not.

1

1

ULA

Unique logical address.
Read only.

The three-switch setting that determines the A16 base address of the PLC-5/VME
processor’s registers.

000 corresponds to FC00,
001 corresponds to FC40,
...,
111 corresponds to FFD0.

1

1

SC

System controller. Read only.

If 1, the PLC-5/VME processor has been configured as the VMEbus slot-1
system controller.

2

1

RELM

VMEbus release mode.
Read only.

If 0, the PLC-5/VME processor has been configured as RWD (release when done);
if 1, the PLC-5/VME processor has been configured as ROR (release on request).

4

1

SLE

Slave enable.
Read only.

If 1, the PLC-5/VME processor’s slave memory in the VMEbus A24 address space has
been enabled.

4

1

SLADDRESS
(HI BYTE)

Read only

Address bits 23-16 of the base address of the PLC-5/VME processor’s slave memory in
the VMEbus A24 address space.

5

1

SLADDRESS

Read only

Address bits 15-0 of the base address of the PLC-5/VME processor’s slave memory in the
VMEbus A24 address space.

1

PLC ladder logic cannot write to statsu file fields that reflect A16 configuration register settings; these fileds are read-only to ladder logic.