Transferring tips – Rockwell Automation 2711E-ND7 PanelView 1400E File Transfer Utility User Manual

Page 12

Advertising
background image

1–4

Introducing the PanelView 1200/1400e Transfer Utility

Publication 2711E-6.8 – January 1998

For PanelView enhanced 1200 (Series F and later) and
1000e/1200e/1400e terminals, in order to do Direct Network
downloads, you must use INTERCHANGE or WINtelligent
LINX drivers. Contact your A-B Sales Representative for details.
Refer to the table in Chapter 5 for a complete list of hardware and
driver requirements.

Note: Refer to the PanelView 1000e, 1200e, and 1400e Operator
Terminals User Manual
for information about the ControlNet
Communication Interface Card requirements for uploading and
downloading over ControlNet.

Remote I/O Pass-Through—Using Remote I/O Pass-Through,
you can upload application files and Alarm History files over
Remote I/O and then over DH+, ControlNet, or Ethernet.

You can download a Remote I/O application between the
PanelView terminal and computer without taking the terminal out
of Run mode or changing the terminal’s serial cabling. Also, you
can print from the PanelView terminal without changing the serial
cabling of the terminal.

For PanelView 1000e/1200e/1400e terminals, in order to do
Remote I/O Pass-Through downloads, you must use RSLinx
drivers. RSLinx is included with your Transfer Utility software
package; however, you must install RSLinx separately. Refer to
the table in Chapter 5 for a complete list of hardware and driver
requirements.

For PanelView enhanced 1200 (Series F and later) and
1000e/1200e/1400e terminals, in order to do Remote I/O
Pass-Through downloads, you must use INTERCHANGE or
WINtelligent LINX drivers. Refer to the table in Chapter 5 for a
complete list of hardware and driver requirements.

Read this section when preparing to transfer an application.

General

For file transfers over ControlNet, DH+, or Remote I/O
Pass-Through, be sure the PanelView terminal address and
control byte is correct, otherwise the transfer could corrupt the
PLC logic.

For all direct transfers (serial or network direct), the
communication parameters of the PanelView 1200/1400e
Transfer Utility driver must match those being used by the
PanelView terminal.

Do not interrupt a download by cycling power during the
operation.

FTU

FTU 32

FTU

"

Transferring Tips