Rockwell Automation 2711E-ND7 PanelView 1400E File Transfer Utility User Manual

Page 49

Advertising
background image

3–10

Uploading 1000e/1200e/1400e Application Files and Alarm History Files

Publication 2711E-6.8 – January 1998

3. To change the settings, press the Baud Rate, Parity, or Error

buttons to move the check mark to the setting you want.

Baud Rate

ĊThe speed at which data is transmitted over the

serial cable. The default setting for a serial transfer is
9600 baud.

Parity

ĊUsed for checking data transferred between the

development computer and terminal. The default setting is
None.

Error

ĊUsed to check for errors in data transmission and is

either

CRC

Ċcyclical (or cyclic) redundancy check.

BCC

Ċblock check character. BCC is the default setting.

4. When you have selected the required settings, press OK to exit

this screen.

5. To upload alarm history serially, press the Transfer Application

button on the Terminal Configuration screen to display the
Transfer Application screen.

The following Transfer Application screen is shown.

Advertising