Rockwell Automation 2711E-ND7 PanelView 1400E File Transfer Utility User Manual

Page 58

Advertising
background image

4–7

Downloading 1000e/1200e/1400e Application Files

Publication 2711E-6.8 – January 1998

To configure the PanelView 1200/1400e Transfer Utility for the
download:

1. Choose Download Application from the PanelView 1200/1400e

Transfer Utility’s Transfer menu, or

from the toolbar.

2. In the File Name field, type the full path and file name of the

download file, or choose Browse to locate a file on the disk. The
file must be a .pvd file created by PanelBuilder 1400e.

3. In the Download As field, type an optional name (up to eight

characters) for your application. This will be the application’s
name on the terminal after the download. All DOS file-naming
restrictions apply.

4. In the Terminal Storage field, choose the area where the

downloaded application will be stored. The default is Memory
Partition 2.

Memory Partition 1 is the terminal’s first memory partition. It is
typically used for firmware storage and is not available for
application file storage, unless the firmware is located on a
PCMCIA card.

Memory Partition 2 is the terminal’s second memory partition.
It is typically used for application file storage.

Card Partition 1 is the first partition on a card with two
application partitions or the partition on the card with a single
partition.

Advertising