5–10

Configuring Communications Settings for 1000e/1200e/1400e Application Transfers

Publication 2711E-6.8 – January 1998

Error
Specify the error-detection protocol used by the device. BCC is
Block Check Character and CRC is Cyclic Redundancy Check.
This must match the error-checking protocol configured for the
PanelView terminal. The default setting is BCC.

For details about PanelView terminal transfer configuration
settings, see “Transferring Application Files” in Chapter 5,
“Configuring PanelView Terminals,” in your PanelView 1000e,
1200e, and 1400e Operator Terminals User Manual
.

Network Direct Transfer Link: Network and Driver
Configuration

When you select Network Direct as the transfer link, Network Type,
Address, and Driver are the options you can configure.

To select the network:

"

Specify Network Type and Address settings as follows:

Type
Specify DH+ or ControlNet as the network to which your PC will
be connected.

When you change network types, some parameter settings may be
invalid. Any invalid parameter settings will change to the default
settings for that selected network type.