Table 5.A Table of PC Host Hardware and Applicable Drivers

If you have this
communication
hardware

Decide which
transfer link to use

Select Network
Type and
Address

Choose one of these
driver packages

Select the corresponding driver

PC COM Port

RS-232 Serial

DF1 Direct

Internal File Transfer
Utility

Serial 1 or 2

WIN LINX

1770-KF2/KE to DH/DH+ & PLC-5 CH0

INTERCHANGE

INTERCHANGE Port 1 – 8

1770-KF2 / KE

Network Direct

DH+

Internal File Transfer
Utility

Serial 1 or 2

WIN LINX

1770-KF2/KE to DH/DH+ & PLC-5 CH0

WIN LINX using INTERCHANGE to DH+

INTERCHANGE

Interchange Port 1 – 8

Remote I/O
Pass-Through

DH+

Internal File Transfer
Utility

Serial 1 or 2

WIN LINX

1770-KF2/KE to DH/DH+ & PLC-5 CH0

WIN LINX using INTERCHANGE to DH+

INTERCHANGE

Interchange Port 1 – 8

1784-KT / KT2 / PCMK

Network Direct

DH+

WIN LINX

1784-KT/KT2/PCMK to DH+

WIN LINX using INTERCHANGE to DH+

INTERCHANGE

Interchange Port 1 – 8

Remote I/O
Pass

ou

DH+

WIN LINX

1784-KT/KT2/PCMK to DH+

Pass-Through

WIN LINX using INTERCHANGE to DH+

INTERCHANGE

Interchange Port 1 – 8

1784-KTX

Network Direct

DH+

WIN LINX

1784-KTX to DH+

WIN LINX using INTERCHANGE to DH+

INTERCHANGE

Interchange Port 1 – 8

Remote I/O
Pass

ou

DH+

WIN LINX

1784-KTX to DH+

Pass-Through

WIN LINX using INTERCHANGE to DH+

INTERCHANGE

Interchange Port 1 – 8

SS Technologies
5 3

Network Direct

DH+

WIN LINX

SS Technologies 5136–SD to DH+

5136-SD

Remote I/O
Pass-Through

DH+

WIN LINX

SS Technologies 5136–SD to DH+

SS Technologies
5 3

Network Direct

DH+

WIN LINX

SS Technologies 5136–SD2 to DH/DH+

5136-SD2

Remote I/O
Pass-Through

DH+

WIN LINX

SS Technologies 5136–SD2 to DH/DH+

FTU

Advertising