5–14

Configuring Communications Settings for 1000e/1200e/1400e Application Transfers

Publication 2711E-6.8 – January 1998

Remote I/O Pass-Through: Transfer Link, Network, Driver, and
Pass-Through Setup Configuration

When you select Remote I/O Pass-Through as the transfer link,
Network Type, Address, Driver, and Pass-Through Setup are the
options you can configure.

To select the network:

"

Specify Network Type and Address settings as follows:

Type
Specify DH+ or ControlNet as the network to which your PC will
be connected.

Specify DH+, ControlNet, or Ethernet as the network to which
your PC will be connected.

When you change network types, some parameter settings may be
invalid. Any invalid parameter settings will change to the default
settings for that selected network type.

Address
This is the station address of the PLC on the DH+, ControlNet, or
Ethernet (for FTU32 only) network. If the PLC is on a different
DH+ network bridged to the PanelBuilder DH+, you must also
specify the full bridge address.

For DH+/Remote I/O Pass-Through, specify the PLC address.
The range is 0 to 77 (octal).

For ControlNet/Remote I/O Pass-Through, specify the PLC
address. The range is 1 to 99 (decimal).