5–18

Configuring Communications Settings for 1000e/1200e/1400e Application Transfers

Publication 2711E-6.8 – January 1998

Rack
Select the rack number that contains the Pass-Through control
byte. Your selection should match the rack number configured in
your application file or PanelView terminal. The default rack is 3.

Word
Select the word in the rack that will contain the Pass-Through
control byte. Your selection should match the word configured in
your application file or PanelView terminal. The default word is 0.

Byte
Specify the High or Low byte of the word that will be used as the
Pass-Through control byte. Your selection should match the byte
configured in your application file or PanelView terminal. The
default byte is Low.

Scanner Slot
If the device is set to SLC 1747-SN Series B, you can also
configure the slot number (0 to 30) used for Pass-Through. Select
0 to use the 1747-SN Ser B scanner installed nearest to the
processor. Select 1 to 30 to use the scanner in the specified slot.

For details about PanelView terminal transfer configuration
settings, see “Transferring Application Files” in Chapter 5,
“Configuring PanelView Terminals” in your PanelView 1000e,
1200e, and 1400e Operator Terminals User Manual
.

To save the communications settings, choose OK from the
Communication Setup dialog box. To return to the factory default
settings, choose Restore Defaults. The factory default settings are
manual mode, serial transfer, and serial 1 driver.

Saving the
Communications Settings