Configuring Communications Settings for 1000e/1200e/1400e Application Transfers

Publication 2711E-6.8 – January 1998

If you have selected a WINtelligent LINX port, selecting the
Setup button opens the WINtelligent LINX utility. Refer to the
WINtelligent LINX user documentation for information on using
the utility.

Note: INTERCHANGE and WINtelligent LINX are not
included in the PanelView 1200/1400e Transfer Utility software
package (A-B Catalog Number 2711E-ND7) and must be
obtained separately. For product information, contact your local
Allen-Bradley office or distributor.

If you have selected a RSLinx port, selecting the Setup button
opens the RSLinx utility. Refer to the RSLinx user documentation
for information on using the utility.

Note: RSLinx is included in the PanelBuilder 1400e software
package (A-B Catalog Number 2711E-ND1) and the PanelView
1200/1400e Transfer Utility software package (A-B Catalog
Number 2711E-ND7).

If you have selected Serial 1 or Serial 2, the Communication
Driver Configuration dialog box appears.

3. Fill in the fields in the Communication Driver Configuration

dialog box as follows:

Baud
Specify the data-transfer rate between your computer and the
PanelView terminal. This must match the baud rate configured
for the PanelView terminal. The default setting is 9600.

Port
Specify COM1, COM2, COM3, or COM4 as the serial port used
to connect the Upload/Download cable or the PanelView
terminal. The default setting is COM1.

Parity
Specify None or Even for the type of error-checking to be used.
This must match the parity configured for the PanelView
terminal. The default setting is None.