Rockwell Automation 7000A PowerFlex Medium Voltage AC Drive (A Frame) - ForGe Control (PanelView 550) User Manual
Page 118
 
3-58 Operator
Interface
7000A-UM151D-EN-P – March 2013
7000 “A” Frame
Figure 3.82 – Transfer File Parameters
The screen will then ask you to confirm the operation. Press the [F8] 
key to proceed, or the [F9] key to abort. Pressing the [F4] key may 
restart an aborted transfer or one that failed. To select or enter a 
different filename, press the [F7] key. 
Download from Memory Card
 
 
The parameters are read from a memory card and written to the drive 
by pressing the [F2] key. The operator interface will enter the 
DIRECTORY screen from which an existing parameter filename can 
be selected or entered. Refer to the sections entitled “Select a 
filename” and “Enter a filename”. When the filename has been 
obtained, the TRANSFER: PARAMETERS screen similar to that 
shown in Figure 3.82 (except the operation will show “FILE TO 
DRIVE”) will be displayed, showing the filename, indicating the 
operation you are about to perform and showing the current status of 
the operation. 
 
 
The screen will then ask you to confirm the operation. Press the [F8] 
key to proceed, or the [F9] key to abort. Pressing the [F4] key may 
restart an aborted transfer or one that failed. To select or enter a 
different filename, press the [F7] key. 
Parameter File Format
 
 
The parameter file stored on the flash card is in a DOS file format. 
This parameter file can be created off-line on a PC using any ASCII 
text editor and then written to the memory card via a PCMCIA Card 
Drive. 
 
 
Information is this section is not needed to operate the operator 
interface. It is required knowledge if you wish to create a parameter 
file off-line and then download into a drive. The filename must have 
the extension of *.PAR in order to be recognized as a parameter file. 
The format of the file is as follows: