Dimensions / weights, Nominal power ratings – Rockwell Automation 7000A PowerFlex Medium Voltage AC Drive (A Frame) - ForGe Control (PanelView 550) User Manual

Page 220

Advertising
background image



F-4 Specifications

7000A-UM151D-EN-P – March 2013

7000 “A” Frame

Dimensions / Weights

Nominal Line

Voltage

Drive Type

VFD

Maximum

Current

Total Width

Approx. Weight

lb (kg)

Millimeters

Inches

2400V 60 Hz

or

3300V 50 Hz

or

4160V 50/60 Hz

Configuration #1 – Direct-to-Drive

140

2100

82.67

4300 (1955)

Configuration #2 – AFE Rectifier with separate isolation

transformer

160 2400

94.49

8300

(3765)

Configuration #3 – AFE Rectifier with Integral isolation

transformer

160 2400

94.49

9800

(4455)

6600V 50/60 Hz

Configuration #1 – Direct-to-Drive

93

2400

94.49

6500 (2955)

Configuration #2 – AFE Rectifier with separate isolation

transformer

105 2800

110.24

10000

(4545)

Configuration #3 – AFE Rectifier with integral isolation

transformer

105 2800

110.24

7500

(3410)

Note:

Total Depth = 1000 mm (39.37 in.)

Total Height without fan shroud = 2318 mm (91.25 in.)

Total Height with fan shroud = 2643 mm (104.05 in.)

Nominal Power Ratings

Nominal Line Voltage

VFD Current Range

(Amps)

Nominal HP Range

Nominal kW Range

2400V 60 Hz

46 – 160

200 – 700

150 – 522

3300V 50 Hz

46 – 160

250 – 1000

187 – 750

4160V 50/60 Hz

46 – 160

350 – 1250

260 – 933

6600V 50/60 Hz

40 – 105

500 - 1250

400 – 933

Advertising