Operator Interface 3-59

7000 “A” Frame

7000A-UM151D-EN-P – March 2013


a)

First

Line:

a revision number followed by a semi-colon (;). Number is

not important.

the date followed by a semi-colon, i.e. 01/01/1996. Date is

not important.

the time followed by a semi-colon, i.e. 12:01:01. Time is not

important.


b)

Remaining

Lines:

each line contains one parameter. The line consists of the

linear parameter number followed by a semi-colon, and the
parameter value followed by a semi-colon. i.e.

1;0;

2;0;

5;2;


Loading Language Modules

In order to use a language in the operator interface, it must first be
loaded into the operator interface from the flash card.


From the TRANSFER screen, press the [F5] key. The operator
interface will enter the DIRECTORY screen, from which an existing
language module filename can be selected or entered, Figure 3.83.
Refer to the sections entitled “Select a filename” and “Enter a
filename”. (If nothing happens then you have not gained the required
access to modify the flash memory. Exit to the TRANSFER screen
and refer to the section entitled Enter/Modify an Access Level to
gain access).


When the filename has been obtained, the TRANSFER:
LANGUAGE screen such as that in Figure 3.84 will be displayed,
showing the filename, indicating the operation you are about to
perform and showing the current status of the operation.

Figure 3.83 – Language Directory