Operator Interface 3-29
7000 “A” Frame
7000A-UM151D-EN-P – March 2013
 
 
 
The screen shown in Figure 3.32 is accessible from within a number 
of screens where the Access Level affects the operation of 
subsequent operations, such as: 
1)
[F10] key on the Top Level Menu,
2)
[F8] key on the Modify Parameter screen,
3)
[F8] key on the Setup Screen,
4)
[F8] key on the Transfer Screen,
5)
[F8] key on the Diagnostic Setup screen.
Figure 3.32 – Access Screen
 
 
The Current Access level is shown. To select a different access 
level, use the up/down cursor keys to select the desired the level. 
Then enter the password value (PIN) for that level using the data 
entry keys. The value can be any number between 0 and 65535. As 
the number is entered via the keys [0]-[9], the value will be shown 
by a placeholder (i.e. * in the editing field), as shown in Figure 3.33. 
Figure 3.33 – Pin Entry
 
 
 
 The value may be edited by using the [backspace] key. When the 
value has been typed in, press the [enter] key. If the correct PIN was 
entered, the access level of the operator interface will change as 
shown in Figure 3.34 . If the incorrect value was entered, the 
operator interface will remain at the current access level.