Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

125

Configure and Start the Kinetix 5500 Drive System

Chapter 6

4. Configure the 842E-CM encoder.

a. Type the encoder Name.
b. Select an Ethernet Address option.

In this example, the Private Network address is selected.

c. Enter the address of your EtherNet/IP module.

In this example, the last octet of the address is 123.

5. Click OK to close the New Module dialog box.

Your 842E-CM encoder appears in the
Controller Organizer under the Ethernet
controller in the I/O Configuration
folder.

6. Click Close to close the Select Module Type dialog box.
7. Right-click the 842E-CM encoder you just created and choose Properties.

The Module Properties dialog box appears.

8. Configure the Associated Axis tab and the motion group for your

842E-CM encoder.

In this example, the feedback-only axis is named
Master_Fdbk.

9. In the Controller Organizer, right-click the feedback-only axis and choose

Properties.

10. Select the General category.

11. From the Module pull-down menu, choose the 842E-CM encoder to

associate with your Feedback Only axis.

The Module Type field populates with the chosen encoder catalog
number.