Apply the Motor Power/brake Shield Clamp

The power/brake cable shield attaches to the drive cable clamp. A clamp spacer is
included with the kit for cable diameters that are too small for a tight fit within
the drive clamp alone.

Routing the conductors with service loops provides stress relief to the

motor power and brake conductors.

Make sure the cable clamp tightens around the cable shield and provides a

good bond between the cable shield and the drive chassis.

Figure 52 - Cable Clamp Attachment

IMPORTANT

If the power/brake cable shield has a loose fit inside the shield clamp, insert
the clamp spacer between the shield clamp and the drive to reduce the
clamp diameter. When the clamp screws are tight, 2.0 N•m (17.7 lb•in), the
result must be a high-frequency bond between the cable shield and the
drive chassis.

Clamp Compressed
Around Shield
(no spacer required)

Insert the clamp spacer when
the cable diameter is smaller
than the drive clamp alone.

Servo Drive

Clamp Spacer (if needed)

Shield Clamp

Clamp Screws
2.0 N•m (17.7 lb•in)

Service Loops

Frame 1

Servo Drive

Frame 2

Servo Drive

Frame 3

Servo Drive

Clamp Spacer Added
(small diameter cable)