Appendix C

Sizing Multi-axis Shared-bus Configurations

Shared AC/DC Configurations

In a shared AC/DC configuration, the first (leftmost) drive receives AC input
voltage. The shared-bus connection system extends the AC and DC bus to all
downstream drives:

All drives are configured in the project file as Shared AC/DC drives.
Drives must be of the same power rating (catalog number).
Shared AC/DC configurations support Bulletin 2198 capacitor modules
Total available converter power is derated by 30%.
The maximum number of drives configured as Shared AC/DC is

described in

Table 87

.

Table 87 - Shared AC/DC Panel Layout

Figure 101 - Typical Shared AC/DC Configuration

For an example shared AC/DC installation with additional details, refer to

Typical Shared AC/DC Installations

on

page 17

.

Drive Cat. No.

Frame Size

Drives Configured as Shared AC/DC, max

(1)

(1) For Bulletin 2198 capacitor module maximum values, refer to the Kinetix 5500 Capacitor Module Installation Instructions,

publication

2198-IN004

.

Number of Capacitor
Modules, max

2198-H003-ERSx

1

8

0

2198-H008-ERSx

1

2198-H015-ERSx

2

4

4

2198-H025-ERSx

2198-H040-ERSx

2198-H070-ERSx

3

2

4

Bonded Cabinet
Ground

Three-phase

Input Power

Kinetix 5500 Servo Drives

(top view)

24V Input

Control Power

DC Bus Connections

2198-CAPMOD-1300 Capacitor Module
(optional component)