Sizing Multi-axis Shared-bus Configurations

Appendix C

Table 86 - Shared DC Panel Layout

Figure 100 - Typical DC Common Bus Configuration

For an example shared DC installation with additional details, refer to

Typical

Shared DC Common-bus Installations

on

page 18

.

Frame Size
Combination

Leader Drive Cat. No.

Follower Drives, max

(1)

Follower Cat. No.

Number of Capacitor
Modules, max

1

2198-H003-ERSx

4

2198-H003-ERSx

0

2198-H008-ERSx

4

2198-H003-ERSx

1

2198-H008-ERSx

1

2 and 1

2198-H015-ERSx

6

2198-H003-ERSx

1

2198-H008-ERSx

2

2198-H015-ERSx

2 and 1

2198-H025-ERSx

6

2198-H003-ERSx

3

2198-H008-ERSx

2

2198-H015-ERSx

2198-H025-ERSx

2 and 1

2198-H040-ERSx

6

2198-H003-ERSx

3

2198-H008-ERSx

2

2198-H015-ERSx

2198-H025-ERSx

2198-H040-ERSx

3 and 1

2198-H070-ERSx

7

2198-H003-ERSx

4

2198-H008-ERSx

3 and 2

2198-H015-ERSx

2198-H025-ERSx

2198-H040-ERSx

3

2198-H070-ERSx

(1) For Bulletin 2198 capacitor module maximum values, refer to the Kinetix 5500 Capacitor Module Installation Instructions, publication

2198-IN004

.

Bonded Cabinet
Ground

Three-phase

Input Power

24V Input

Control Power

2198-H040-ERSx

Common-bus Leader Drive

2198-H008-ERSx

Common-bus

Follower Drives

2198-CAPMOD-1300 Capacitor Module
(optional component)

DC Bus Connections

IMPORTANT

Total number of drives in Kinetix 5500 drive system must not exceed 8.