Capacitor module connections – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 95

Advertising
background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

95

Connecting the Kinetix 5500 Drive System

Chapter 5

Capacitor Module
Connections

Follow these guidelines when wiring the 2198-CAPMOD-1300 capacitor
module:

Wire relay output (MS) connections to the Logix5000 controller

(optional).

Refer to

Kinetix 5500 Capacitor Module

wiring example on

page 191

.

Refer to

Kinetix 5500 Capacitor Module Status Indicators

on

page 147

for

troubleshooting the module status indicator and relay output.

Refer to the installation instructions provided with your Bulletin 2198

capacitor module, publication

2198-IN004

.

Figure 55 - Capacitor Module Wiring

Table 48 - Capacitor Module Connector Specifications

IMPORTANT

To improve system performance, run wires and cables in the wireways as
established in

Chapter 2

.

Connections to the DC bus and 24V control power must be made with the
shared-bus connection system.

2
1

3

4

1

2

Kinetix 5500 Capacitor Module
Top View

Kinetix 5500 Capacitor Module
Front View

Item

Description

1

Module status (MS) connector (relay output)

2

Module status indicator

3

DC bus (DC) connector (under cover)

(1)

(2)

(1) The DC bus connector ships with a protective knock-out cover

that can be removed for use in shared-bus configurations.

(2) The shared-bus connector set for the capacitor module, catalog

number 2198-KITCON-CAP1300, is included for connection to the
upstream drive. Replacement kits are also available.

4

24V control input power (CP) connector

(2)

Capacitor Module
Cat. No.

Pin

Signal

Recommended
Wire Size
mm

2

(AWG)

Strip Length
mm (in.)

Torque Value
N•m (lb•in)

2198-CAPMOD-1300

MS-1

RELAY+

0.14…1.5
(28…16)

7.0 (0.28)

0.22…0.25
(1.9…2.2)

MS-2

RELAY-

Advertising