Disable soft overtravel limit, Ladder code example, Disable soft overtravel limit ladder code example – Rockwell Automation MPMA Integrated Multi-Axis Linear Stages User Manual

Page 119

Advertising
background image

Rockwell Automation Publication MPMA-UM001B-EN-P - November 2010

119

Home to Torque-level Example

Appendix D

Disable Soft Overtravel

Limit

If the application requires the use of soft-overtravel limits (Limits tab) to
safeguard the system mechanics, disable the Soft Travel Limits for the axis to
home. The Soft Travel Limits are disabled to prevent a fault from occurring
during the homing operation, but re-enable them after homing completes.

Ladder Code Example

This example shows how to adjust the peak torque limit and disable the soft-
overtravel limit checking when homing to a torque limit. The code uses a state
model methodology in which each rung of code needs to complete successfully
before moving to the next rung.

Rung 11 of the ladder code checks to make sure that the axis position, after
homing, is within the Soft Travel Limits before re-enabling soft-overtravel limit
checking. In this example, a 1.15 cm Offset move is configured in the Homing tab
and that is the final home position. The 0.5 cm is within the Soft Travel Limits
set on the Limits tab.

Table 53 - Tags Used

IMPORTANT

Those responsible for the application must determine when it is
safe and appropriate to disable soft-overtravel checking.

IMPORTANT

Because the home to torque-level sequence relies on the
mechanical end of travel for operation, Uni-directional homing is
not possible. You must choose between Forward Bi-directional or
Reverse Bi-directional.

Tag Name

Data Type

Description

Saved_FaultConfig

DINT

Storage location for FaultConfigurationBits (motion attributes)
Bit 0 = soft-overtravel limit checking

Clear_SoftOT_Mask

DINT Set

to

-2.

This masks the off soft-overtravel enable bit without changing the other configuration bits.

Temp_FaultConfig

DINT

Temporary hold word for FaultConfigurableBits

SoftOT_Disabled

BOOL

Soft-overtravel checking disabled status bit

Saved_TQLim_Bipolar REAL

Storage

location for Peak Torque (TorqueLimitBipolar)

HomeTQ_Level

REAL

Home Torque Level from the Home tab in Axis Properties

Temp_TQLim_Bipolar

REAL

Temporary Peak Torque for Homing (10% higher than Home Torque Limit)

Axis_01_MI.MAH

MOTION_INSTRUCTION

Control for MAH instruction (using a UDT)

Positive_Overtravel REAL

Max

Positive Soft-overtravel value

Negative_Overtravel

REAL

Max Negative Soft-overtravel value

Saved_PosErrorTol

REAL

Storage location for Actual Position Error value

Temp_PosErrorTol

REAL

Temporary Position Error value for Homing