Configuration Guidelines

Chapter 6

7.

In the Motor Encoder Units pull-down menu, enter the appropriate values
from the tables on

page 59

.

Velocity, position, and acceleration counts per unit are based on the selected User
Units (mm or in.).

Table 4 - Direct Drive Linear Stage Distance Unit Settings

User Unit Scaling Parameters

(1)

(1) User units are determined by the screw lead of the linear stage. The screw lead is defined in linear units of

travel per revolution. For example, the travel per revolution of an

MPAS-xxxxxx-V20xxx

is 20 mm/rev. MP-

Series Integrated Linear Stages with a ball screw use a feedback device that provides 128 sin/cos cycles per
revolution of the motor. The Ultra3000 drive interpolates this signal by an additional 1024, causing the
maximum count per internal motor revolution of the linear stage to be 131,072 counts/rev.

Distance Units for Ball Screw Linear Stages

Metric

English

MPAS-xxxxxx-V20xxx

MPAS-xxxxxx-V20xxx

Velocity Label

mm/s

in./s

Velocity Scale

6553.6

166461.44

Position Label

mm

in.

Position Scale

6553.6

166461.44

Acceleration Label

mm/s/s

in./s/s

Acceleration Scale

6553.6

166461.44

User Unit Scaling Parameters

Distance Units
Metric

English

Velocity Label

mm/s

in./s

Velocity Scale

200

5080

Position Label

mm

in.

Position Scale

200

5080

Acceleration Label

mm/s/s

in./s/s

Acceleration Scale

200

5080