Chapter 3 Planning a Multi-axis Stage Installation

Mounting Orientations for Center and Cantilever Multi-axis Stage XY
(
MPMA-xA/Cxxxxxx-SxC)

Mounting Orientations for Center Stacked XZ Multi-axis Stage (MPMA-
x
Bxxxxxx-SxC)

Mounting

Orientation

Restriction

Ceiling - inverted
surface

A ceiling mount (inverted on a horizontal surface) is not recommended.
Stages mounted in this orientation are subject to premature cable carrier
failure.

Wall - horizontal
vertical or incline

Use only center stacked XZ multi-axis stage for wall mounting applications.

Mounting

Orientation

Restriction

Ceiling - inverted
surface

A ceiling mount (inverted on a horizontal surface) is not recommended.
Stages mounted in this orientation are subject to premature cable carrier
failure.

Wall - horizontal
vertical or incline

Mount center stacked XZ multi-axis stages with the ball screw driven stage
in the Z-axis only. Application of the holding brake through the operating
program settings prevents uncontrolled motion.