Lubricate the bearing – Rockwell Automation MPMA Integrated Multi-Axis Linear Stages User Manual

Page 62

Advertising
background image

62

Rockwell Automation Publication MPMA-UM001B-EN-P - November 2010

Chapter 7 Maintenance

Lubricate the Bearing

Lubricate the linear stage bearings as shown and described below. Use the MP-
Series Integrated Linear Stage grease pump kit, and additional grease cartridges as
necessary.

Figure 11 - Direct Drive Linear Stage Lubrication

Figure 12 - Ball Screw Linear Stage Lubrication

1.

Position the carriage at end of travel and clamp it to hold the linear stage
against end block.

2.

Remove the lubrication port protective caps on each end cap.

3.

Insert the tip of the grease pump into the lubrication port, pushing in until
firm contact with the grease fitting is made.

4.

Pump the handle until back pressure is felt, or a maximum of two strokes
are made.

ATTENTION: Do not use clamp across the side panels. This will
deform and damage the side panels.

Bearing Lubrication Ports (two per end cap)

Bearing Lubrication Ports (two per end cap)

Ball Nut Lubrication Port
(one per linear stage)