Chapter 7: maintenance, Introduction, Before you begin – Rockwell Automation MPMA Integrated Multi-Axis Linear Stages User Manual

Page 61: Recommended maintenance intervals, Maintenance, Chapter

Advertising
background image

Rockwell Automation Publication MPMA-UM001B-EN-P - November 2010

61

Chapter

7

Maintenance

Introduction

This chapter describes the maintenance procedures for your linear stage.

Before You Begin

You will need the following tools to lubricate and clean your linear stage:

0.36 m (14 in.) or larger clamp with soft jaws
Grease pump kit (catalog number MPAS-GPUMP) with tip type installed

and primed

Grease cartridge (catalog number MPAS-CART), included in grease

pump kit.

Air line with a maximum pressure of 68 kpa (10 psi).
Lint free cloth
Isopropyl alcohol, as necessary for cleaning

Recommended

Maintenance Intervals

Recommended maintenance and lubrication intervals are:

direct drive linear stages every 6 months or 2500 km (1550 mi) of travel,

whichever comes first

ball screw linear stages every 6 months or 150,000,000 revolutions,

whichever comes first

Topic Page

Before You Begin

61

Recommended Maintenance Intervals

61

Lubricate the Bearing

62

Clean the Strip Seal

63

Clean the Cover

63

IMPORTANT

Any person that teaches, operates, maintains, or repairs these
linear stages must be trained and demonstrate the competence to
safely perform the assigned task.

ATTENTION: Lockout and tagout input power before servicing.

Advertising