2.
Torque the ground screw at the lower stage to 2 N•m (18 lb•in.).
3.
Form a drip loop in each cable at a point directly before it attaches to the
motor.
M5 x 0.8 -6H
Ground Screw
Braided Ground Wire 12 mm (0.5 in.) min.
Lug
Align Flat Surfaces
Power/Brake
Connector
Feedback
Connector
Drip Loop
in Cable