Hapter, Configuring the interbus scanner – Rockwell Automation RECOMM-IBUS Interbus Communications Module User Manual
Page 31

Configuring the Interbus Scanner
5-1
C
HAPTER
5
Configuring the
Interbus Scanner
A scanner is a separate module of a multi-module controller or a
built-in component of a single-module controller that provides
communication with a module connected to a network.
Interbus scanners are available from several manufacturers,
including SST. Chapter 5 provides instructions on how to use
Phoenix Contact CMD software to configure the network on an SST
scanner.
5.1
Configuring a Simple Network:
An Example
All examples in this manual are based on the following:
•
SLC controller with an SST Interbus scanner (SST-IBS-SLC)
in slot 1.
•
SP600 drive at Device 1.0 / CR 2 (CR# is needed for PCP
commands).
•
SP600 drive at Device 2.0 / CR 3 (CR# is needed for PCP
commands).
•
Logic Command/Status, Reference/Feedback and Datalinks A-D
are enabled in the RECOMM-IBUS and mapped to network
I/O.
•
Phoenix Contact CMD software is used to configure the network.
This chapter describes the steps to configure a simple network like
the one featured in figure 5.1.