Configuring the Interbus Scanner

5-9

Step 13. Right-click on the SST-IBS-SLC scanner and select

Process Data. This shows the Interbus I/O mapping for
each device on the network, as shown in figure 5.12.

In the example, the length is 144 bits (9 words) because the
RECOMM-IBUS was previously configured for the maximum I/O
configuration. (See section 4.3, Setting the I/O Configuration.
Depending on your application needs, this length may be less.)
The scanner mapping correlates to SLC addressing as shown in
figure 5.13.

Figure 5.12 – Sample Interbus I/O Mapping

Figure 5.13 – Scanner Mapping / SLC Addressing

(USC/4) Output SLC (USC/4) Input SLC

0
1

63
64
65

511

O:x.0(high)
O:x.0(low)

O:x.31(low)
M0:x.0(high)
M0:x.0(low)

M0:x.223(low)

512
513

575
576

1023

I:x.0(high)
I:x.0(low)

I:x.31(low)
M1:x.0(high)
M1:x.0(low)

M1:x.223(low)

Scanner

Scanner