Interbus Communications Module
I/O that is transferred through the module.
7
Reserved
Range:
N/A
Default:
N/A
Type:
N/A
Reset Required: N/A
8
DPI I/O Config
Range:
See figure B.1.
Default:
See figure B.1.
Type:
Read/Write
Reset Required: N/A
Figure B.1 – DPI I/O Config (8)
!
ATTENTION: If the module is transmitting I/O that
controls the drive, the drive may fault when you reset
the module. Determine how your drive will respond
before resetting a connected module. Failure to
observe this precaution could result in bodily injury
or damage to equipment.
0
0
0
1
0
x
x
x
0
1
2
3
4
5
6
7
1 = I/O Enabled
0 = I/O Disabled
x =Not Used
Cmd/Ref
Datalink A
Datalink B
Datalink C
Datalink D
Not Used
Not Used
Not Used