Ul safety standards for linear stage installations, Mounting restrictions – Rockwell Automation MPAS Integrated Linear Stages User Manual

Page 24

Advertising
background image

24

Rockwell Automation Publication MP-UM001D-EN-P - September 2013

Chapter 3

Planning Your Installation

UL Safety Standards for Linear Stage Installations

All linear stage installations must follow UL 1740 - Standard for Safety for
Robots and Robotic Equipment.

UL 1740 covers robots and robotic equipment rated at 600V or less and intended
for installation in accordance with the National Electrical Code, ANSI/NFPA
70. Because end user installation of a robot and robotic equipment can vary for
each user application, guidelines for end-product installation can be evaluated to
the applicable sections of ANSI/RIA R15.06, Standard for Industrial Robots and
Robot Systems-Safety Requirements. Portions of the requirements in this
standard have been excerpted from the Robotic Industries Association's (RIA)
Standard for Industrial Robots and Robot Systems – Safety Requirements,
ANSI/RIA R15.06.

ANSI/RIA R15.06 specifically requires two safety features be in the design.

A Power Enable light must be installed that meets all of these conditions:

Must be amber or yellow in color.
Must not have a screw type base or contain a filament.
Must be visible from all approaches to the work cell.
Must illuminate to indicate that drive power is available and motion is

possible.

For example, an Allen-Bradley 855T Control Tower Stack Light can be
used with socket mount status indicators. Incandescent bulbs are not
permitted.

Provide a means of emergency movement without drive power available.

This must include a provision for a brake release on a ball screw linear
stage.

For additional information, refer to the

Emergency Brake Release for Ball

Screw Linear Stage Example

on

page 38

.

Unique features or functions associated with the robotic application, not
specifically addressed in UL 1740, shall also be evaluated to other applicable
standards and requirements. These can include, but are not limited to the
following:

UL 3101-1, Electrical Equipment for Laboratory Use; Part 1: General

Requirements

UL 544, Medical and Dental Equipment
UL 79, Power Operated Pumps for Petroleum Product Dispensing

Systems

ANSI/NFPA 79, Electrical Standard for Industrial Machinery

Mounting Restrictions

When locating your MPAS stage include the following:

Advertising