Rotary motor replacement – Rockwell Automation MPAS Integrated Linear Stages User Manual

Page 66

Advertising
background image

66

Rockwell Automation Publication MP-UM001D-EN-P - September 2013

Chapter 8

Removing and Replacing Components

Rotary Motor Replacement

Follow these directions to replace a rotary motor.

1. Disconnect the motor cables.
2. Remove the four M5 SHCS and lock washers that secure the motor to the

linear stage.

3. Remove the motor.

4. Mark the measured coupling position on the new motor shaft.
5. Loosen the M4 SHCS in the coupling and remove the coupling from old

motor shaft.

6. Position the coupling on the new motor shaft, align it with the mark made

in step 4, and then tighten the coupling.

7. Align the coupling halves and install the motor.
8. Secure the motor with four M5 SHCS and lock washers.
9. Torque each cap screw to 4 N•m (35 lb•in), by using a diagonal tightening

sequence.

IMPORTANT

Measure the position of the coupling on the motor shaft as shown in
panel B of the diagram above.

M5 SHCS (4x)

A

B

M4 SHCS

Advertising