Side cover installation – Rockwell Automation MPAS Integrated Linear Stages User Manual

Page 65

Advertising
background image

Rockwell Automation Publication MP-UM001D-EN-P - September 2013

65

Removing and Replacing Components

Chapter 8

9. Move the carriage by hand through the complete range of travel and make

sure the strip seal seats smoothly against the cover and side panel magnet
strips.

Pulling against the tightened end clamp helps to smooth the seal.

10. Once the seal lays flat and smooth against the top cover and side panel,

tighten the second end clamp.

11. With the outside edge of the end clamps as a guide, use tin snips to cut and

remove excess strip seal material.

12. Position the carriage at the far ends of travel.
13. Adjust the seal guide by inserting a 0.8 mm (0.03 in.) shim between the

seal guide and the strip seal.

14. Return the linear stage to service.

Side Cover Installation

Follow these directions to install a side cover.

1. Insert a side cover into the base of the linear stage by holding it with the

top slightly tilted outward and hooking the bottom of the side cover in the
channel near the bottom of the base.

2. Starting at the end cap adjacent to the ground screw, install one M4 SHCS

and torque it to 4 N•m (35 lb•in).

3. On the opposite end, install one M3 SHCS and torque it to 2.5 N•m

(20 lb•in).

Seal Guide

0.8 mm (0.03 in.) Shim

Strip Seal

TIP

If installing the side cover with strip seals in place use a flat-blade screwdriver
to lift the side cover by inserting the screwdriver under the cover between the
cover and the base.

Advertising