Bearing Lubrication

Lubricate the linear stage bearings as shown and described below. Use the MP-
Series Integrated Linear Stage grease pump kit, and additional grease cartridges as
necessary.

Figure 12 - Direct Drive Linear Stage Lubrication

Figure 13 - Ball Screw Linear Stage Lubrication

1. Position the carriage at end of travel and clamp it to hold the linear stage

against end block.

2. Remove the lubrication port protective caps on each end cap.
3. Insert the tip of the grease pump into the lubrication port, pushing in until

firm contact with the grease fitting is made.

4. Pump the handle until back pressure is felt, or a maximum of two strokes

are made.

5. Repeat step 3 and step 4 to the other lubrication ports.
6. Move the carriage to opposite end of travel and repeat steps 1…5.

ATTENTION: Do not use clamp across the side panels. This deforms and
damages the side panels.

Bearing Lubrication Ports (two per end cap)