Chapter 7 - maintenance, Before you begin, Recommended maintenance intervals – Rockwell Automation MPAS Integrated Linear Stages User Manual

Page 57: Chapter 7, Maintenance, Before you begin recommended maintenance intervals, For lu, Chapter

Advertising
background image

Rockwell Automation Publication MP-UM001D-EN-P - September 2013

57

Chapter

7

Maintenance

Before You Begin

Use the following tools to lubricate and clean your linear stage.

0.36 meter (14 inches) or larger clamp with soft jaws
Grease pump kit (catalog number MPAS-GPUMP) with tip type installed

and primed

Grease cartridge (catalog number MPAS-CART), included in grease

pump kit.

Air line having a maximum pressure of 68 kPa (10 psi)

.

Lint-free cloth
Isopropyl alcohol, as necessary for cleaning

Recommended Maintenance
Intervals

Recommended maintenance and lubrication intervals are:

direct drive linear stages every 6 months or 5000 km of travel, whichever

comes first

ball screw linear stages every 3 months or 150,000,000 revolutions,

whichever comes first

Topic Page

Before You Begin

57

Recommended Maintenance Intervals

57

Bearing Lubrication

58

Strip Seal Cleaning

59

Cover Cleaning

59

IMPORTANT

Any person that teaches, operates, maintains, or repairs these linear
stages must be trained and demonstrate the competence to safely
perform the assigned task.

ATTENTION: Lockout and tagout input power before servicing.

Advertising