Rockwell Automation MPAS Integrated Linear Stages User Manual

Page 48

Advertising
background image

48

Rockwell Automation Publication MP-UM001D-EN-P - September 2013

Chapter 6

Configuration Guidelines

Tuning Linear Stages by Using the Logix Designer Application

This section documents the steps necessary to tune linear stages by using the
RSLogix 5000 software, version 16.xx or the Logix Designer application.

Tuning your linear stage requires you to calculate and configure the loop

gain based on the actual measured inertia.

Setting travel limits defines the minimum deceleration for your specific

application.

Tune Your Linear Stage

Set the following parameters in the Axis Properties tab of the Logix Designer
application to tune a ball screw drive linear stage (catalog number MPAS-

xxxxxx-

V

xxSxA).

1. In the Axis Properties dialog box, click Fault Actions >

Set Custom Stop Action > Custom Stop Attributes.

Homing Mode Active

Position 0

(or

programmable)

Offset

5 mm, min

0.2 in., min

Sequence Torque

Level-to-marker

Direction Reverse

Bi-directional

Torque Level

50%, min
Greater if the system friction, force, or weight exceeds 50% of the Continuous Force Rating at any point in the range
of motion.

Speed 50 mm/s

1.97 in./s

Return Speed

10 mm/s

0.39 in./s

Absolute Home is available for ball screw linear stages. For maximum range of motion, position the carriage so its proximal edge is 25.4 mm (1.0 in.)
from the inside edge of the end plate.

Software or Hardware Limits

Negative Limit

or

Positive Limit

Use Motion Analyzer to determine maximum stopping distance in your application

Axis Properties Tab

Parameter

Entry/Selection, with applicable distance unit settings

Millimeters Inches

IMPORTANT

ATTENTION: The Tuning and Loop Gain procedures apply to only the ball
screw linear stages.

The Travel Limit procedures apply to both the direct drive and the ball screw
linear stages.

IMPORTANT

These procedures apply to only ball screw linear stages.

TIP

These parameter settings work best if the linear stage is installed in a
horizontal (table top) or a wall mount (vertical) orientation.

Advertising