Chapter 6

Configuration Guidelines

Motor Feedback

Feedback Type

TTL with Hall

Cycles 50

Per Millimeter

Conversion

Positioning Mode

Linear

Conversion Constant

200 drive counts / 1.0 mm

5080 drive counts / 1.0 in.

Hookup

(1)

Test Increment

70 mm, min for Ultra3000 drive
20 mm Kinetix 2000 drive
20 mm Kinetix 6000 drive

2.76 in. min for Ultra3000 drive
0.787 in. Kinetix 2000 drive
0.787 in. Kinetix 6000 drive

Drive Polarity

Positive (see definition)

Homing Mode Active

Position 0

(or

programmable)

Offset

5 mm, min

0.2 in., min

Sequence Torque

Level-to-Marker

Direction Reverse

Bi-directional

Torque Level

80%, min
Greater if the system friction, force, or weight exceeds 80% of the Continuous Force Rating at any point in the range
of motion

Speed 50 mm/s

1.97 in/s

Return Speed

10 mm/s

0.39 in/s

Software or Hardware Limits

Negative Limit

or

Positive Limit

Use Motion Analyzer to determine the maximum stopping distance in your application

(1) The Command and Feedback test, accessed from the Hookup tab, does not verify the Hall Sensor wiring to a Kinetix 2000 or a Kinetix 6000 drive. The wire colors and continuity for the Hall signals must be

manually verified.

Axis Properties Tab

Parameter

Entry/Selection, with applicable distance unit settings

Millimeters

Inches

(+)

(-)

(+)

(-)