Ball screw drive stages – Rockwell Automation MPAS Integrated Linear Stages User Manual

Page 47

Advertising
background image

Rockwell Automation Publication MP-UM001D-EN-P - September 2013

47

Configuration Guidelines

Chapter 6

Ball Screw Drive Stages

Set these parameters in the appropriate Axis Properties tab of the Logix Designer
application for ball screw linear stages, catalog number MPAS-

xxxxxx-VxxxxA.

Axis Properties Tab

Parameter

Entry/Selection, with applicable distance unit settings

Millimeters Inches

Drive/Motor

Motor Catalog Number

Select one from the list
MPAS-Axxxx1-V05S2A
MPAS-Axxxx1-V05S4A
MPAS-Axxxx2-V20S2A
MPAS-Axxxx2-V20S4A
MPAS-Bxxxx1-V05S2A
MPAS-Bxxxx1-V05S4A
MPAS-Bxxxx2-V20S2A
MPAS-Bxxxx2-V20S4A

Drive Resolution

200,000

Drive Counts per

Motor Millimeter

Conversion Positioning

Mode

Linear

ATTENTION: Setting the Positioning Mode to Rotary can cause damage to the stage or
the machine due to incorrect positioning.

Conversion Constant

40,000 drive counts / 1.0 mm for

1,016,000 drive counts / 1.0 in. for

MPAS-Axxxx1-V05S2A
MPAS-Axxxx1-V05S4A
MPAS-Bxxxx1-V05S2A
MPAS-Bxxxx1-V05S4A

Conversion Constant

10,000 drive counts / 1.0 mm for

254,000 drive counts / 1.0 in. for

MPAS-Axxxx2-V20S2A
MPAS-Axxxx2-V20S4A
MPAS-Bxxxx2-V20S2A
MPAS-Bxxxx2-V20S4A

Hookup Test

Increment

5 mm min

0.2 in., min

Drive Polarity

Positive (see definition)

(+)

(-)