Configuration Guidelines
Chapter 6
Ball Screw Drive Stages
Set these parameters in the appropriate Axis Properties tab of the Logix Designer
application for ball screw linear stages, catalog number MPAS-
xxxxxx-VxxxxA.
Axis Properties Tab
Parameter
Entry/Selection, with applicable distance unit settings
Millimeters Inches
Drive/Motor
Motor Catalog Number
Select one from the list
MPAS-Axxxx1-V05S2A
MPAS-Axxxx1-V05S4A
MPAS-Axxxx2-V20S2A
MPAS-Axxxx2-V20S4A
MPAS-Bxxxx1-V05S2A
MPAS-Bxxxx1-V05S4A
MPAS-Bxxxx2-V20S2A
MPAS-Bxxxx2-V20S4A
Drive Resolution
200,000
Drive Counts per
Motor Millimeter
Conversion Positioning
Mode
Linear
ATTENTION: Setting the Positioning Mode to Rotary can cause damage to the stage or
the machine due to incorrect positioning.
Conversion Constant
40,000 drive counts / 1.0 mm for
1,016,000 drive counts / 1.0 in. for
MPAS-Axxxx1-V05S2A
MPAS-Axxxx1-V05S4A
MPAS-Bxxxx1-V05S2A
MPAS-Bxxxx1-V05S4A
Conversion Constant
10,000 drive counts / 1.0 mm for
254,000 drive counts / 1.0 in. for
MPAS-Axxxx2-V20S2A
MPAS-Axxxx2-V20S4A
MPAS-Bxxxx2-V20S2A
MPAS-Bxxxx2-V20S4A
Hookup Test
Increment
5 mm min
0.2 in., min
Drive Polarity
Positive (see definition)
(+)
(-)