Chapter 3

Planning Your Installation

Mounting Orientations for Ball Screw Linear Stages

Clearance Requirements

The figures depict the minimum clearances for each stage type.

Power and feedback cables can impose additional clearance requirements. Refer
to

Installation, Maintenance, and Replacement Kits on page 83

for connector

and bend radius requirements.

Figure 5 - Minimum Clearance Requirements

Mounting Orientation

Restriction

Ceiling - inverted surface

A ceiling mount (inverted on a horizontal surface) must be of the covered and sealed configuration, and have a travel of 300 mm (11.8 in.) or
less.

Wall - horizontal

A horizontal wall mount stages must be of the covered and sealed configuration.

Wall - vertical or incline

Vertical wall mount or inclined stages must have a brake option. Application of the holding brake option through operating program settings
prevents uncontrolled motion.

419 mm (16.5 in.) Clearance Both Ends for Lubrication Access

3.2 mm (0.125 in.) Clearance Around Entire Stage

MPAS-xxxxxxx-ALMx2C

MPAS-xxxxxxx-VxxSxA

Additional clearance is required for power
and feedback cables.